FEST-B 2v1 NA STŘECHY S2141
SINGLE COAT FOR IRON
Solvent-based single coat uses for protective and decorative coatings in exterior: metal roofing, eaves, metal works exposed weather conditions and sunshine. It contains corrosion inhibitor and UV radiation absorber. Painting of galvanized sheet is possible after one year of weathering.
SURFACE PREPARATION
The surface has to be clean, dry and free of grease, rust and dust. Degrease by technical benzene P 6402, acetone P 6401 or hot water with detergent. Salt residue rinse with water. Defective or poorly adhering impurities remove by grinding or scraping, thoroughly remove rust (metal brush, grindstone, rust remover). Rust remover rinse by water.
Porous materials impregnate for uniform absorbency of the surface.
Previously painted surfaces clean, degrease and remove all poorly adhering old coats to the solid surface when renovate. Verify compatibility between old paint and new one. Perform a test on the area 1 m2.
THINNER S 6006 for brush or roller, S 6001 for spraying
RECOMMENDED APPLICATION
Mix properly before use.
Apply 1-2 coats (spraying) of FEST-B S2141 with optimal film thickness of one coat 50 µm. Following coat applies “wet to wet” till 3 hours or after drying 24 hours.
Coverage
7-8 m²/kg in one coat
Application
- Brush
- Spray
- Roller